     tool           chamber         status              異常原因                         處理方式
______________________________________________________________________________________________________________________
HDP103A         ALL               DOWN            連線異常              

1.install ATHENA KB fail導致CISA毀損, 目前機台無法連線,vendor目前正在處理中。

HDP101A           A                 IDLE             IN S/D P/H                  

1.test run 2 lots,data OK,tool release。

HDP201A          A/B                PM           chamber wet clean     
                                                             &change dome

1.when CHB run PTC clean,PEC發生滑片.
2.執行error recovery退回CHC(SFA00617)
3.check vacuum robot hand off、robot status、PEC surface、pedestal up&down OK.
4.CHA/B wet clean&change dome OK
5.leak rate:CHA:0.7856 mT/min CHB:0.7068mT/min
6.heat up now
7.預計6:30下dummy
8.pls中夜班trace monitor data.
9.PM time 2/14 07:00-2/16 07:00
_______________________________________________________________________________________________________________________